LS/4.16.1 Intelligent Lighting Control Module - Centralized Lighting Control System for Residential Areas, Schools, and Factories
Contact Info
- Add:柳市柳黄路1600, Zip:
- Contact: 吉经理
- Tel:0577-27877837
- Email:2392076794@qq.com
Other Products
LS/4.16.1 Intelligent Lighting Control Module - Centralized lighting control system for residential areas, schools, and factoriesCapable of dimming various types of light source fixtures with excellent intelligent dimming performance. It can control different types of lights (such as incandescent lamps, low-voltage lamps, fluorescent lamps, metal halide lamps, LED lights, etc.), featuring soft start, adjustment of main power supply voltage, compensation for main power frequency changes, and suppression of electromagnetic interference. The intelligent lighting dimmer offers multiple dimming curves for users to choose from, with an efficiency of over 90%.
Building RenovationEasy installation, saves cables: C-Bus is a two-wire lighting control system that uses a pair of UTP Cat5 cables as the control bus to connect various input, output, and support units. Large cross-section load cables are directly connected from the output unit to the lighting fixtures or other electrical loads without passing through switches. Through room controllers, all room status information is uploaded to the host, allowing service personnel to promptly address customer needs based on room status. Control can be achieved with control panels.Juchuan Electric I36342993I3.
Equipped with Chinese LCD display: Menu-based full Chinese interface allows easy parameter settings and scene calling with function keys.
2. Equipped with scene and timing control functions: 6 user-defined scenes and 1 user-defined timing sequence.
3. Equipped with astronomical time control function: Also known as astronomical clock function, after selection, the switching time of lighting equipment automatically adjusts according to sunrise and sunset times throughout the year.
4. Equipped with independent automatic control function: With the addition of illuminance or human motion detectors, combined control of illuminance, time, etc., can be achieved.
5. Equipped with bypass mechanical switch function: Each circuit relay in the controller has a small toggle switch, allowing forced opening or closing of a circuit in case of failure.
6. Equipped with circuit fault detection function: When the actual current value of a circuit is below the normal current value, it indicates a fault in the circuit's lighting fixture, triggering an alarm window to remind personnel for maintenance (only available with current detection module).
7. Equipped with data synchronization function: When activated with one click, the controller's perpetual calendar time, scene circuit status, and latitude/longitude settings will match the parameters set by the host computer.
8. Equipped with fire alarm linkage control function: Upon receiving a fire emergency start signal, all emergency lighting circuits are forcibly activated.
9. Adjustable circuit switching time interval: The interval time for sequentially turning on/off each circuit of the controller can be set, adjustable from 0.1S to 2S.
10. Equipped with zero-crossing disconnect function: Optional modules with current detection can have zero-crossing disconnect function.
11. Automatic control: Sensors installed in public areas such as parking lots, corridors, and stair halls enable automatic control. Sensors monitor whether vehicles/people enter or leave the current environment; if no vehicle moves or no person walks, the lights remain off; when a vehicle moves or a person walks, lights in the controlled area turn on, and turn off with a delay after the person/vehicle leaves.
12. Manual control: Smart panels and touchscreens installed in locations like duty rooms, elevator entrances, and rooms enable on-site manual control. Panels/touchscreens can achieve one-to-one or one-to-many control. Lights controlled on-site can also be centrally controlled via computer.
13. Scene control: LS/4.16.1 Intelligent Lighting Control Module - Centralized lighting control system for residential areas, schools, and factoriesThe system pre-sets various scene modes based on different control requirements, and scene switching can be set on panels/touchscreens/central control interfaces. During normal operation, staff can freely switch between scenes.
14. Timed control: For projects with relatively fixed usage times, such as landscape lighting, office buildings, banks, and schools. Timed switching can be set according to customer needs or user habits for turning lights on/off, achieving automatic control of the lighting system and ensuring minimal energy consumption during off-peak hours.
15. Fire linkage: Can be integrated with fire alarm systems for联动 control. When a fire alarm signal is received, emergency lights are forcibly activated, providing light for safe evacuation.
16. Centralized computer monitoring: All LS/4.16.1intelligent lightingcircuits can be centrally controlled via computer, with real-time feedback on the switching status of on-site circuits, facilitating remote monitoring by duty personnel.
17. Simple and smart: The system is easy to use and automatically adjusts based on environmental changes.
18. Luxurious and comfortable: The control panels are aesthetically designed with attractive colors, and the system can create a charming atmosphere.
19. Practical and economical: The system functions are practical, and integrated control significantly saves building energy.
20. Safe and reliable: Control circuits and load circuits are separated, with the control circuit operating at a safe voltage of DC12V, ensuring personal safety even in case of accidental leakage from switch panels.
21. Coordinated and flexible: The system can be customized and modified according to user needs.
22. Open and compatible: Multiple integration methods with building control systems, easy system upgrades and maintenance.
23 Standard rail-mounted installation occupies 8 modular spaces;
24 Provides 6 channels of 16A (20A) relay switches, each capable of independently controlling 3500W equipment switching;
25 Can set the initial value for each circuit upon startup;
26 Features multi-circuit sequential delayed startup function to avoid power grid impact from simultaneous startups;
27 Sets two groups of interlock modes, capable of controlling 3 groups of curtains;
28 Sets 3 interlock modes, capable of controlling low, medium, and high speeds of two central air conditioners;
29 Immediately returns the actual switching status of each circuit to the monitoring center after executing scene commands;
30 Supports local and remote programming and testing functions;
31 Includes emergency switch buttons for convenient debugging;
32 Equipped with circuit status indicators for clear visibility of switching status;
33 Supports online program updates;
34 Uses CAN-BUS bus communication.
| Industry Category | Electrical-Equipment-Supplies |
|---|---|
| Product Category | |
| Brand: | ADR |
| Spec: | LS/4.16.1 |
| Stock: | 500 |
| Manufacturer: | |
| Origin: | China / Zhejiang / Wenzhoushi |